import os, sys
|
|
|
import datetime
|
|
|
import time
|
|
|
from schainpy.controller import Project
|
|
|
path = '/home/alex/Downloads/NEW_WR2/spc16removeDC'
|
|
|
figpath = path
|
|
|
desc = "Simulator Test"
|
|
|
|
|
|
controllerObj = Project()
|
|
|
|
|
|
controllerObj.setup(id='10', name='Test Simulator', description=desc)
|
|
|
|
|
|
readUnitConfObj = controllerObj.addReadUnit(datatype='SimulatorReader',
|
|
|
frequency=9.345e9,
|
|
|
FixRCP_IPP=60,
|
|
|
Tau_0=30,
|
|
|
AcqH0_0=0,
|
|
|
samples=330,
|
|
|
AcqDH_0=0.15,
|
|
|
FixRCP_TXA=0.15,
|
|
|
FixRCP_TXB=0.15,
|
|
|
Fdoppler=600.0,
|
|
|
Hdoppler=36,
|
|
|
Adoppler=300, # 300
|
|
|
delay=0,
|
|
|
online=0,
|
|
|
walk=0,
|
|
|
profilesPerBlock=625,
|
|
|
dataBlocksPerFile=100) # ,#nTotalReadFiles=2)
|
|
|
'''
|
|
|
readUnitConfObj = controllerObj.addReadUnit(datatype='VoltageReader',
|
|
|
path=path,
|
|
|
startDate="2020/01/01", #"2020/01/01",#today,
|
|
|
endDate= "2020/12/01", #"2020/12/30",#today,
|
|
|
startTime='00:00:00',
|
|
|
endTime='23:59:59',
|
|
|
delay=0,
|
|
|
#set=0,
|
|
|
online=0,
|
|
|
walk=1)
|
|
|
'''
|
|
|
opObj11 = readUnitConfObj.addOperation(name='printInfo')
|
|
|
|
|
|
procUnitConfObjA = controllerObj.addProcUnit(datatype='VoltageProc', inputId=readUnitConfObj.getId())
|
|
|
# opObj11 = procUnitConfObjA.addOperation(name='CohInt', optype='other')
|
|
|
# opObj11.addParameter(name='n', value='10', format='int')
|
|
|
|
|
|
# opObj10 = procUnitConfObjA.addOperation(name='selectChannels')
|
|
|
# opObj10.addParameter(name='channelList', value=[0])
|
|
|
opObj11 = procUnitConfObjA.addOperation(name='PulsePairVoltage', optype='other')
|
|
|
opObj11.addParameter(name='n', value='625', format='int') # 10
|
|
|
opObj11.addParameter(name='removeDC', value=1, format='int')
|
|
|
|
|
|
# opObj11 = procUnitConfObjA.addOperation(name='PulsepairPowerPlot', optype='other')
|
|
|
# opObj11 = procUnitConfObjA.addOperation(name='PulsepairSignalPlot', optype='other')
|
|
|
|
|
|
|
|
|
# opObj11 = procUnitConfObjA.addOperation(name='PulsepairVelocityPlot', optype='other')
|
|
|
# opObj11.addParameter(name='xmax', value=8)
|
|
|
|
|
|
# opObj11 = procUnitConfObjA.addOperation(name='PulsepairSpecwidthPlot', optype='other')
|
|
|
|
|
|
procUnitConfObjB = controllerObj.addProcUnit(datatype='ParametersProc', inputId=procUnitConfObjA.getId())
|
|
|
|
|
|
|
|
|
opObj10 = procUnitConfObjB.addOperation(name='ParameterWriter')
|
|
|
opObj10.addParameter(name='path', value=figpath)
|
|
|
# opObj10.addParameter(name='mode',value=0)
|
|
|
opObj10.addParameter(name='blocksPerFile', value='100', format='int')
|
|
|
opObj10.addParameter(name='metadataList', value='utctimeInit,timeInterval', format='list')
|
|
|
opObj10.addParameter(name='dataList', value='dataPP_POW,dataPP_DOP,dataPP_SNR,dataPP_WIDTH') # ,format='list'
|
|
|
|
|
|
controllerObj.start()
|
|
|
|