##// END OF EJS Templates
Update version, fix kwargs for self operations (methods), Add SendToWeb...
Update version, fix kwargs for self operations (methods), Add SendToWeb operation to publish plots arguments

File last commit:

r583:e5ed8fbe1d1e
r906:a52f011a763e
Show More
150km_jicamarca.xml
60 lines | 3.7 KiB | application/xml | XmlLexer
Miguel Valdez
Bug plotting RTI fixed: timezone was removed from getLimit function
r566 <Project description="150 km Jicamarca January 2015" id="191" name="test01">
<ReadUnit datatype="VoltageReader" id="1911" inputId="0" name="VoltageReader">
<Operation id="19111" name="run" priority="1" type="self">
<Parameter format="str" id="191111" name="path" value="./" />
<Parameter format="date" id="191112" name="startDate" value="2015/01/14" />
<Parameter format="date" id="191113" name="endDate" value="2015/01/14" />
<Parameter format="time" id="191114" name="startTime" value="08:30:00" />
<Parameter format="time" id="191115" name="endTime" value="09:30:59" />
<Parameter format="int" id="191116" name="delay" value="10" />
<Parameter format="int" id="191117" name="nTxs" value="4" />
<Parameter format="int" id="191118" name="walk" value="1" />
<Parameter format="int" id="191119" name="online" value="1" />
</Operation>
<Operation id="19112" name="printNumberOfBlock" priority="2" type="self" />
</ReadUnit>
<ProcUnit datatype="SpectraProc" id="1913" inputId="1912" name="SpectraProc">
<Operation id="19131" name="run" priority="1" type="self">
<Parameter format="int" id="191311" name="nFFTPoints" value="80" />
<Parameter format="int" id="191312" name="nProfiles" value="80" />
<Parameter format="pairslist" id="191313" name="pairsList" value="(1,0),(3,2),(5,4),(7,6)" />
</Operation>
<Operation id="19132" name="IncohInt" priority="2" type="other">
<Parameter format="float" id="191321" name="timeInterval" value="60" />
</Operation>
<Operation id="19133" name="CrossSpectraPlot" priority="3" type="other">
<Parameter format="int" id="191331" name="id" value="2006" />
<Parameter format="str" id="191332" name="wintitle" value="CrossSpectraPlot_ShortPulse" />
<Parameter format="int" id="191333" name="ymin" value="0" />
<Parameter format="int" id="191334" name="ymax" value="105" />
<Parameter format="str" id="191335" name="phase_cmap" value="jet" />
<Parameter format="int" id="191336" name="zmin" value="15" />
<Parameter format="int" id="191337" name="zmax" value="45" />
<Parameter format="str" id="191338" name="figpath" value="/Users/miguel/tmp" />
<Parameter format="int" id="191339" name="exp_code" value="13" />
</Operation>
<Operation id="19134" name="CoherenceMap" priority="4" type="other">
<Parameter format="int" id="191341" name="id" value="102" />
<Parameter format="str" id="191342" name="wintitle" value="Coherence" />
<Parameter format="str" id="191343" name="phase_cmap" value="jet" />
<Parameter format="float" id="191344" name="xmin" value="8.5" />
<Parameter format="float" id="191345" name="xmax" value="9.5" />
<Parameter format="str" id="191346" name="figpath" value="/Users/miguel/tmp" />
<Parameter format="bool" id="191347" name="save" value="1" />
<Parameter format="pairslist" id="191348" name="pairsList" value="(1,0),(3,2)" />
</Operation>
</ProcUnit>
<ProcUnit datatype="VoltageProc" id="1912" inputId="1911" name="VoltageProc">
<Operation id="19121" name="run" priority="1" type="self" />
<Operation id="19122" name="ProfileSelector" priority="2" type="other">
<Parameter format="multilist" id="191221" name="rangeList" value="(1,80),(341,420),(681,760),(1021,1100)" />
</Operation>
<Operation id="19123" name="Decoder" priority="3" type="other">
<Parameter format="floatlist" id="191231" name="code" value="1,1,1,-1,-1,1,-1,1,1,1,-1,-1,1,-1,-1,-1,-1,1,1,-1,1,-1,-1,-1,1,1,-1,1" />
<Parameter format="int" id="191232" name="nCode" value="4" />
<Parameter format="int" id="191233" name="nBaud" value="7" />
</Operation>
<Operation id="19124" name="deFlip" priority="4" type="self">
<Parameter format="intlist" id="191241" name="channelList" value="1,3,5,7" />
</Operation>
</ProcUnit>
</Project>