##// END OF EJS Templates
23/11/2017
23/11/2017

File last commit:

r1027:f11c2da27e74
r1123:72ed20327727
Show More
schain.xml
1 line | 2.9 KiB | application/xml | XmlLexer
<Project description="Segundo Test" id="191" name="test01"><ReadUnit datatype="VoltageReader" id="1911" inputId="0" name="VoltageReader"><Operation id="19111" name="run" priority="1" type="self"><Parameter format="str" id="191111" name="datatype" value="VoltageReader" /><Parameter format="str" id="191112" name="path" value="/home/erick/Documents/Data/Claire_Data/raw" /><Parameter format="date" id="191113" name="startDate" value="2017/07/26" /><Parameter format="date" id="191114" name="endDate" value="2017/07/26" /><Parameter format="time" id="191115" name="startTime" value="10:02:00" /><Parameter format="time" id="191116" name="endTime" value="10:11:00" /><Parameter format="int" id="191118" name="online" value="0" /><Parameter format="int" id="191119" name="walk" value="1" /></Operation><Operation id="19112" name="printNumberOfBlock" priority="2" type="self" /></ReadUnit><ProcUnit datatype="SpectraProc" id="1913" inputId="1912" name="SpectraProc"><Operation id="19131" name="run" priority="1" type="self"><Parameter format="int" id="191311" name="nFFTPoints" value="128" /><Parameter format="pairslist" id="191312" name="pairsList" value="(0,1),(0,2),(1,2)" /></Operation><Operation id="19132" name="removeDC" priority="2" type="self" /><Operation id="19133" name="IncohInt" priority="3" type="external"><Parameter format="float" id="191331" name="n" value="30" /></Operation><Operation id="19134" name="CrossSpectraPlot" priority="4" type="other"><Parameter format="str" id="191341" name="phase_cmap" value="bwr" /><Parameter format="int" id="191342" name="id" value="2005" /><Parameter format="str" id="191343" name="wintitle" value="CrossSpectraPlot_ShortPulse" /><Parameter format="str" id="191344" name="xaxis" value="Velocity" /><Parameter format="float" id="191345" name="ymin" value="1" /><Parameter format="int" id="191346" name="ymax" value="7" /><Parameter format="int" id="191347" name="zmin" value="15" /><Parameter format="int" id="191348" name="zmax" value="60" /><Parameter format="int" id="191349" name="save" value="2" /><Parameter format="str" id="191350" name="figpath" value="/media/erick/6F60F7113095A154/CLAIRE/CLAIRE_WINDS_2MHZ/Images" /></Operation></ProcUnit><ProcUnit datatype="VoltageProc" id="1912" inputId="1911" name="VoltageProc"><Operation id="19121" name="run" priority="1" type="self" /><Operation id="19122" name="setRadarFrequency" priority="2" type="self"><Parameter format="float" id="191221" name="frequency" value="445.09e6" /></Operation><Operation id="19123" name="selectHeights" priority="3" type="self"><Parameter format="float" id="191231" name="minHei" value="0" /><Parameter format="float" id="191232" name="maxHei" value="64" /></Operation></ProcUnit><ProcUnit datatype="Parameters" id="1914" inputId="1913" name="ParametersProc"><Operation id="19141" name="run" priority="1" type="self" /><Operation id="19142" name="GaussianFit" priority="2" type="other" /></ProcUnit></Project>