testProcMIRA35c.py.svn-base
98 lines
| 4.0 KiB
| text/plain
|
TextLexer
|
r965 | #!/usr/bin/env python | ||
import os, sys | ||||
path = os.path.dirname(os.getcwd()) | ||||
path = os.path.join(path, 'source') | ||||
sys.path.insert(0, '../') | ||||
from controller import Project | ||||
xmin = '15.5' | ||||
xmax = '24' | ||||
desc = "ProcBLTR Test" | ||||
filename = "ProcBLTR.xml" | ||||
controllerObj = Project() | ||||
controllerObj.setup(id = '191', name='test01', description=desc) | ||||
readUnitConfObj = controllerObj.addReadUnit(datatype='MIRA35CReader', | ||||
path='/home/erick/Documents/MIRA35C/20160117', | ||||
startDate='2016/11/8', | ||||
endDate='2017/10/19', | ||||
startTime='13:00:00', | ||||
endTime='23:59:59', | ||||
online=0, | ||||
walk=0, | ||||
ReadMode='1') | ||||
#expLabel='') | ||||
#opObj11 = readUnitConfObj.addOperation(name='printNumberOfBlock') | ||||
procUnitConfObj1 = controllerObj.addProcUnit(datatype='Spectra', inputId=readUnitConfObj.getId()) | ||||
opObj11 = procUnitConfObj1.addOperation(name='IncohInt', optype='other') | ||||
opObj11.addParameter(name='n', value='1', format='float') | ||||
opObj10 = procUnitConfObj1.addOperation(name='removeDC') | ||||
#opObj10 = procUnitConfObj1.addOperation(name='calcMag') | ||||
# #opObj10 = procUnitConfObj1.addOperation(name='selectChannels') | ||||
# #opObj10.addParameter(name='channelList', value='0,1', format='intlist') | ||||
opObj11 = procUnitConfObj1.addOperation(name='SpectraPlot', optype='other') | ||||
opObj11.addParameter(name='id', value='21', format='int') | ||||
opObj11.addParameter(name='wintitle', value='SpectraPlot', format='str') | ||||
opObj11.addParameter(name='xaxis', value='Velocity', format='str') | ||||
opObj11.addParameter(name='xaxis', value='velocity', format='str') | ||||
opObj11.addParameter(name='xmin', value='-0.005', format='float') | ||||
opObj11.addParameter(name='xmax', value='0.005', format='float') | ||||
#opObj11.addParameter(name='ymin', value='225', format='float') | ||||
#opObj11.addParameter(name='ymax', value='3000', format='float') | ||||
# opObj11.addParameter(name='zmin', value='-100', format='int') | ||||
# opObj11.addParameter(name='zmax', value='-65', format='int') | ||||
#opObj11 = procUnitConfObj1.addOperation(name='RTIPlot', optype='other') | ||||
#opObj11.addParameter(name='id', value='10', format='int') | ||||
#opObj11.addParameter(name='wintitle', value='RTI', format='str') | ||||
# opObj11.addParameter(name='ymin', value='0', format='float') | ||||
# opObj11.addParameter(name='ymax', value='4000', format='float') | ||||
##opObj11.addParameter(name='zmin', value='-100', format='int') | ||||
##opObj11.addParameter(name='zmax', value='-70', format='int') | ||||
# opObj11.addParameter(name='zmin', value='-90', format='int') | ||||
# opObj11.addParameter(name='zmax', value='-40', format='int') | ||||
#opObj11.addParameter(name='showprofile', value='1', format='int') | ||||
#opObj11.addParameter(name='timerange', value=str(2*60*60), format='int') | ||||
# opObj11 = procUnitConfObj1.addOperation(name='CrossSpectraPlot', optype='other') | ||||
# #procUnitConfObj1.addParameter(name='pairsList', value='(0,1),(0,2),(1,2)', format='pairsList') | ||||
# opObj11.addParameter(name='id', value='2005', format='int') | ||||
# opObj11.addParameter(name='wintitle', value='CrossSpectraPlot_ShortPulse', format='str') | ||||
# # opObj11.addParameter(name='exp_code', value='13', format='int') | ||||
# opObj11.addParameter(name='xaxis', value='Velocity', format='str') | ||||
# #opObj11.addParameter(name='xmin', value='-10', format='float') | ||||
# #opObj11.addParameter(name='xmax', value='10', format='float') | ||||
# #opObj11.addParameter(name='ymin', value='225', format='float') | ||||
# #opObj11.addParameter(name='ymax', value='3000', format='float') | ||||
# #opObj11.addParameter(name='phase_min', value='-4', format='int') | ||||
# #opObj11.addParameter(name='phase_max', value='4', format='int') | ||||
controllerObj.createObjects() | ||||
controllerObj.connectObjects() | ||||
controllerObj.run() | ||||