Opened 8 years ago
Last modified 8 years ago
#295 new Reception
12 Apr 17:00 Test of D and C reception lines — at Initial Version
Reported by: | imanay | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2017 JULIA |
Component: | JULIA | Version: | |
Keywords: | Cc: | ||
Parent Tickets: |
Description
Due to 150km echoes at the D channel lower than C, these reception lines were tested with a noise generator (Attached the connections of this test).
For the following cables, these results were obtained at the acquisition system:
- 50 ohmios load instead of noise generator:
C 7.98
D 8.06
- Using noise generator:
C D
16.41 12.00
(4,4.75)m (4,5.5)m
17.05 16.66
(4,4)m (4,4.75)m
15.78 17.48
(4,4.75)m (4,4)m
15.17 12.94
(4,4.75)m (4,5.5)m
Subtickets (add)