﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc	parents
295	12 Apr 17:00 Test of D and C reception lines	imanay		"Due to 150km echoes at the D channel lower than C, these reception lines were tested with a noise generator (Attached the connections of this test).
For the following cables, these results were obtained at the acquisition system:

1. 50 ohmios load instead of noise generator:

||C||7.98||
||D||8.06||

2. Using noise generator:


||      C       ||      D       ||
||    16.41     ||   12.00      ||
||   (4,4.75)m  ||  (4,5.5)m    ||

||    17.05     ||    16.66     ||
||   (4,4)m     ||   (4,4.75)m  ||

||    15.78     ||    17.48     ||
||   (4,4.75)m  ||  (4,4)m      ||

||    15.17     ||   12.94      ||
||   (4,4.75)m  ||  (4,5.5)m    ||
"	Reception	new	normal	2017 JULIA	JULIA					