﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc	parents
295	12 Apr 17:00 Test of D and C reception lines	imanay		"Due to 150km echoes at the D channel lower than C, these reception lines were tested with a noise generator (Attached the connections of this test).
For the following cables, these results were obtained at the acquisition system:

1. 50 ohmios load instead of noise generator:

C   7.98

D   8.06

2. Using noise generator:


      C          D

    16.41       12.00
   (4,4.75)m    (4,5.5)m

    17.05       16.66
   (4,4)m      (4,4.75)m

    15.78       17.48
   (4,4.75)m    (4,4)m

    15.17       12.94
   (4,4.75)m    (4,5.5)m
"	Reception	new	normal	2017 JULIA	JULIA					