Mediciones de ruido de canales de JULIA:

  1. Desde sala de operaciones
Canal50 ohmios5 mA (-41dB)10 mA (-38dB)3dB
(dB)
C7.4212.4614.412.02
7.4112.4014.47
12.3214.37
D7.8412.4214.362
7.8912.4214.37
7.8712.2714.42
E8.811.2213.061.83
8.7911.2313.05
11.2113.04
  1. Desde antena
50 ohmios5 mA (-41dB)10 mA (-38dB)3dB
(dB)
A11.4115.4817.542.03
11.7915.4617.54
11.8415.6117.54
B10.5215.1517.292.11
10.5015.1117.19
10.5115.1417.26
C7.8411.0112.721.72
7.8810.9712.76
7.7711.0312.71
D8.0710.712.331.63
8.0210.6712.33
8.110.7112.33
E7.8210.811.540.7
7.8310.8211.52
7.8410.7911.5

Debido al cambio de 5 a 10 mA, la variación del canal E es pequeña comparada con los otros canales: Aprox. 0.7 dB