﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc	parents
207	13 Dic 2013 12:10 Se repone JULIA_EW	imanay	imanay	"__Mediciones de ruido de canales de JULIA:__

A. Desde sala de operaciones
||=Canal=||=50 ohmios=||=5 mA (-41dB)=||=10 mA (-38dB)||=3dB=||
|| ||=(dB)=||= =||= =||= =||
||=C=||=7.42=||=12.46=||=14.41=||=2.02=||
|| ||=7.41=||=12.40=||=14.47||= =||
|| || ||=12.32=||=14.37=||= =||
||=D=||=7.84=||=12.42=||=14.36=||=2=||
|| ||=7.89=||=12.42=||=14.37=||= =||
|| ||=7.87=||=12.27=||=14.42=||= =||
||=E=||=8.8=||=11.22=||=13.06=||=1.83=||
|| ||=8.79=||=11.23=||=13.05=||= =||
|| || ||=11.21=||=13.04=||= =||

B. Desde antena

|| ||=50 ohmios=||=5 mA (-41dB)=||=10 mA (-38dB)=||=3dB=||
|| ||=(dB)=||= =||= =||= =||
||=A=||=11.41=||=15.48=||=17.54=||=2.03=||
|| ||=11.79=||=15.46=||=17.54=||= =||       
|| ||=11.84=||=15.61=||=17.54=||= =||
||=B=||=10.52=||=15.15=||=17.29=||=2.11=||
|| ||=10.50=||=15.11=||=17.19=||= =||
|| ||=10.51=||=15.14=||=17.26=||= =||
||=C=||=7.84=||=11.01=||=12.72=||=1.72=||
|| ||=7.88=||=10.97=||=12.76=||= =||
|| ||=7.77=||=11.03=||=12.71=||= =||
||=D=||=8.07=||=10.7=||=12.33=||=1.63=||
|| ||=8.02=||=10.67=||=12.33=||= =||
|| ||=8.1=||=10.71=||=12.33=||= =||
||=E=||=7.82=||=10.8=||=11.54=||=0.7=||
|| ||=7.83=||=10.82=||=11.52=||= =||
|| ||=7.84=||=10.79=||=11.5=||= =||

Debido al cambio de 5 a 10 mA, la variación del canal E es pequeña comparada con los otros canales: Aprox. 0.7 dB"	Reception	new	normal	2013 Sistema JULIA	Sistema JULIA					