931	08 Feb 07:10 Transmitter power measurements	rtadeo		"07/02/2016
20:00 TX Power sample (-70 dB coupling)
Tx1 +6.8 dBm
Tx4 +6.8 dBm
Dr2 -6.3 dBm
Line voltage and power: 4000 VAC, 360 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +6.8 dBm
Tx4 +6.8 dBm
Dr2 -6.3 dBm
Line voltage and power: 4000 VAC, 360 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +6.8 dBm
Tx4 +6.8 dBm
Dr2 -6.3 dBm
Line voltage and power: 4000 VAC, 360 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +6.8 dBm
Tx4 +7.0 dBm
Dr2 -6.3 dBm
Line voltage and power: 4050 VAC, 360 KW
08/02/2016
00:00 TX Power sample (-70 dB coupling)
Tx1 +6.8 dBm
Tx4 +7.0 dBm
Dr2 -6.3 dBm
Line voltage and power: 4050 VAC, 360 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +6.8 dBm
Tx4 +6.9 dBm
Dr2 -6.3 dBm
Line voltage and power: 4050 VAC, 360 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +6.8 dBm
Tx4 +6.9 dBm
Dr2 -6.3 dBm
Line voltage and power: 4050 VAC, 360 KW
02:20 imaging OFF
02:55 Imaging ON  -6.5 dBm
03:00 TX Power sample (-70 dB coupling)
Tx1 +6.8 dBm
Tx4 +7.0 dBm
Dr2 -6.5 dBm
Line voltage and power: 4090 VAC, 360 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +6.8 dBm
Tx4 +7.0 dBm
Dr2 -6.5 dBm
Line voltage and power: 4090 VAC, 360 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +6.8 dBm
Tx4 +7.0 dBm
Dr2 -6.5 dBm
Line voltage and power: 4090 VAC, 360 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +6.8 dBm
Tx4 +7.0 dBm
Dr2 -6.5 dBm
Line voltage and power: 4090 VAC, 360 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +6.8 dBm
Tx4 +7.0 dBm
Dr2 -6.5 dBm
Line voltage and power: 4090 VAC, 360 KW
07:13 Imaging OFF
"	Transmitters	new	normal	2016_02_1 ISCOD Gravity Waves	ISR				