﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
90	14 Feb 23:55 Transmitter Power Measurements	vquesada		"20:00 TX Power sample (-70 dB coupling)
Tx1 +5.9 dBm
Tx2 +1.9 dBm
Tx4 +2.1 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 300 KW

'''20:16 driver Tx1 OFF, problem in pulse of EW_Drifts.
20:20 HV OFF
22:38 HV ON'''

22:40 TX Power sample (-70 dB coupling)
Tx1 +5.9 dBm
Tx2 +1.9 dBm
Tx4 +2.1 dBm
D3 -5.6 dBm
Line voltage and power: 4020 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.9 dBm
Tx2 +2.0 dBm
Tx4 +2.3 dBm
D3 -5.6 dBm
Line voltage and power: 4050 VAC, 300 KW"	Start experiment	new	normal		ISR				