﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
756	14 Jan 07:00 Transmitter power measurements	vquesada		"00:00 TX Power sample (-70 dB coupling)
Tx1 +4.7 dBm
Tx4 +4.7 dBm
Line voltage and power: 4020 VAC, 330 KW
00:08 HP Tx1 flow fault sensor
01:00 TX Power sample (-70 dB coupling)
Tx1 +4.6 dBm
Tx4 +4.6 dBm
Line voltage and power: 4000 VAC, 330 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +4.6 dBm
Tx4 +4.6 dBm
Line voltage and power: 4000 VAC, 330 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +4.6 dBm
Tx4 +4.6 dBm
Line voltage and power: 4000 VAC, 330 KW
03:10 HP Tx1 flow fault sensor
04:00 TX Power sample (-70 dB coupling)
Tx1 +4.7 dBm
Tx4 +4.6 dBm
Line voltage and power: 4000 VAC, 330 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +4.6 dBm
Tx4 +4.6 dBm
Line voltage and power: 4000 VAC, 330 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +4.6 dBm
Tx4 +4.6 dBm
Line voltage and power: 3950 VAC, 320 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +4.7 dBm
Tx4 +4.7 dBm
Line voltage and power: 4000 VAC, 330 KW"	Transmitters	new	normal	2016_01_2 Gyro Synchro	ISR				