Opened 9 years ago
#585 new Transmitters
01 Oct 17:20 Transmitter power measurements
Reported by: | rtadeo | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2015_09_2 MST-ISR-EEJ |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
08:00 TX Power sample (-70 dB coupling)
Tx2 +4.1 dBm
Tx4 +4.2 dBm
Line voltage and power: 3950 VAC, 300 KW
09:00 TX Power sample (-70 dB coupling)
Tx2 +4.0 dBm
Tx4 +4.1 dBm
Line voltage and power: 3920 VAC, 300 KW
10:00 TX Power sample (-70 dB coupling)
Tx2 +4.0 dBm
Tx4 +4.1 dBm
Line voltage and power: 3920 VAC, 300 KW
11:00 TX Power sample (-70 dB coupling)
Tx2 +4.0 dBm
Tx4 +4.1 dBm
Line voltage and power: 3920 VAC, 300 KW
12:00 TX Power sample (-70 dB coupling)
Tx2 +4.0 dBm
Tx4 +4.1 dBm
Line voltage and power: 3920 VAC, 300 KW
13:00 TX Power sample (-70 dB coupling)
Tx2 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 3850 VAC, 290 KW
14:00 TX Power sample (-70 dB coupling)
Tx2 +3.6 dBm
Tx4 +3.9 dBm
Line voltage and power: 3850 VAC, 290 KW
15:00 TX Power sample (-70 dB coupling)
Tx2 +3.4 dBm
Tx4 +3.8 dBm
Line voltage and power: 3850 VAC, 290 KW
16:00 TX Power sample (-70 dB coupling)
Tx2 +3.5 dBm
Tx4 +3.9 dBm
Line voltage and power: 3850 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
Tx2 +3.9 dBm
Tx4 +4.1 dBm
Line voltage and power: 3940 VAC, 300 KW
18:00 TX Power sample (-70 dB coupling)
Tx2 +4.0 dBm
Tx4 +4.1 dBm
Line voltage and power: 4000 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
Tx2 +4.1 dBm
Tx4 +4.2 dBm
Line voltage and power: 4000 VAC, 300 KW