Opened 9 years ago

#551 new Transmitters

25 Set 08:00 Transmitter Power Measurement

Reported by: vquesada Owned by:
Priority: normal Milestone: 2015_09_1 Support CNOFS
Component: ISR Version:
Keywords: Cc:

Description

00:00 TX Power sample (-70 dB coupling)
Tx1 +6.4 dBm
Tx2 +2.1 dBm
Tx4 +2.3 dBm
D3 -6.1 dBm
Line voltage and power: 3950 VAC, 310 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +6.4 dBm
Tx2 +2.1 dBm
Tx4 +2.3 dBm
D3 -6.1 dBm
Line voltage and power: 3950 VAC, 310 KW
01:12 Driver 3 OFF
02:00 TX Power sample (-70 dB coupling)
Tx1 +6.4 dBm
Tx2 +5.4,2.2 dBm
Tx4 +2.4 dBm
Line voltage and power: 3950 VAC, 310 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +6.4 dBm
Tx2 +5.4,2.2 dBm
Tx4 +2.4 dBm
Line voltage and power: 3950 VAC, 310 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +6.3 dBm
Tx2 +5.3,2.0 dBm
Tx4 +2.2 dBm
Line voltage and power: 3950 VAC, 310 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +6.3 dBm
Tx2 +5.3,2.0 dBm
Tx4 +2.2 dBm
Line voltage and power: 3950 VAC, 310 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +6.4 dBm
Tx2 +5.3,2.1 dBm
Tx4 +2.2 dBm
Line voltage and power: 3940 VAC, 310 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +6.4 dBm
Tx2 +5.3,2.1 dBm
Tx4 +2.2 dBm
Line voltage and power: 3940 VAC, 310 KW
08:00 HV OFF
08:15 LV OFF

Change History (0)

Note: See TracTickets for help on using tickets.