Opened 9 years ago

#547 new Transmitters

24 Set 23:00 Transmitter Power Measurement

Reported by: vquesada Owned by:
Priority: normal Milestone: 2015_09_1 Support CNOFS
Component: ISR Version:
Keywords: Cc:

Description

20:00 TX Power sample (-70 dB coupling)
Tx1 +6.3 dBm
Tx2 +1.9 dBm
Tx4 +2.2 dBm
D3 -6.0 dBm
Line voltage and power: 3960 VAC, 310 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +6.3 dBm
Tx2 +1.9 dBm
Tx4 +2.2 dBm
D3 -6.0 dBm
Line voltage and power: 3960 VAC, 310 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +6.3 dBm
Tx2 +1.9 dBm
Tx4 +2.2 dBm
D3 -6.0 dBm
Line voltage and power: 3960 VAC, 310 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +6.3 dBm
Tx2 +1.9 dBm
Tx4 +2.2 dBm
D3 -6.0 dBm
Line voltage and power: 3960 VAC, 310 KW

Change History (0)