Opened 9 years ago
#494 new Transmitters
28 Aug 08:00 Transmitter Power Measurement
Reported by: | vquesada | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2015_08 Support CNOFS |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
00:00 TX Power sample (-70 dB coupling)
Tx1 +6.4 dBm
Tx2 +1.3 dBm
Tx4 +1.9 dBm
D3 -7.1 dBm
Line voltage and power: 4080 VAC, 310 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +6.4 dBm
Tx2 +1.3 dBm
Tx4 +1.9 dBm
D3 -7.1 dBm
Line voltage and power: 4080 VAC, 310 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +6.6 dBm
Tx2 +1.7 dBm
Tx4 +2.2 dBm
D3 -7.0 dBm
Line voltage and power: 4090 VAC, 310 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +6.6 dBm
Tx2 +1.7 dBm
Tx4 +2.2 dBm
D3 -7.0 dBm
Line voltage and power: 4090 VAC, 310 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +6.5 dBm
Tx2 +1.6 dBm
Tx4 +2.1 dBm
D3 -7.1 dBm
Line voltage and power: 4050 VAC, 310 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +6.5 dBm
Tx2 +1.6 dBm
Tx4 +2.1 dBm
D3 -7.1 dBm
Line voltage and power: 4050 VAC, 310 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +6.7 dBm
Tx2 +1.7 dBm
Tx4 +2.2 dBm
D3 -7.0 dBm
Line voltage and power: 4090 VAC, 310 KW
06:25 Driver 3 OFF
07:00 TX Power sample (-70 dB coupling)
Tx1 +6.7 dBm
Tx2 +1.6,5.2 dBm
Tx4 +2.2 dBm
Line voltage and power: 4090 VAC, 310 KW
08:07 HV OFF
08:20 LV OFF