Opened 10 years ago

#48 new Transmitters

11 Feb 19:25 Transmitter power measurement

Reported by: ryaya Owned by:
Priority: normal Milestone: 2015_02 ISR + Imaging (ISCOD)
Component: ISR Version:
Keywords: Cc:

Description

09:00 TX Power sample (-70 dB coupling)
1 +5.8 dBm
2 +2.2 dBm/ +5.6 dBm
4 +2.4 dBm
Voltage line and power: 4080 VAC, 300 KW
09:20 Problem at PA 1 Screen power supply
12:00 TX Power sample (-70 dB coupling)
1 +5.8 dBm
2 +2.1 dBm/ +5.6 dBm
4 +2.4 dBm
Voltage line and power: 4060 VAC, 310 KW
14:00 TX Power sample (-70 dB coupling)
1 +5.7 dBm
2 +2.1 dBm/ +5.6 dBm
4 +2.4 dBm
Voltage line and power: 4010 VAC, 300 KW
15:00 TX Power sample (-70 dB coupling)
1 +5.7 dBm
2 +2.1 dBm/ +5.6 dBm
4 +2.4 dBm
16:00 TX Power sample (-70 dB coupling)
1 +5.7 dBm
2 +2.0 dBm/ +5.6 dBm
4 +2.4 dBm
Voltage line and power: 4080 VAC, 300 KW
17:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.0 dBm/ +5.6 dBm
4 +2.4 dBm
Voltage line and power: 4020 VAC, 300 KW
17:40 Driver 3 ON (IMAGING)
18:00 TX Power sample (-70 dB coupling)
1 +5.8 dBm
2 +2.1 dBm
4 +2.4 dBm
D3 -5.6 dBm
Voltage line and power: 4050 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
1 +6.0 dBm
2 +2.1 dBm
4 +2.4 dBm
D3 -5.6 dBm
Voltage line and power: 4080 VAC, 300 KW

Change History (0)