Opened 9 years ago

#436 new Transmitters

22 Jul 19:45 Transmitter power measurements

Reported by: ryaya Owned by:
Priority: normal Milestone: 2015_07_2 Support ISR School
Component: ISR Version:
Keywords: Cc:

Description

09:00 TX Power sample (-70 dB coupling)
Tx1 +6.8 dBm
Tx2 +1.6,3.7 dBm
Tx4 +1.2 dBm
Line voltage and power: 4020 VAC, 300 KW
09:14 RF OFF (Adq. request)
09:46 RF ON
10:00 TX Power sample (-70 dB coupling)
Tx1 +6.7 dBm
Tx2 +1.6,3.7 dBm
Tx4 +1.3 dBm
Line voltage and power: 4020 VAC, 300 KW
10:27 RF OFF (Radar school request)
11:05 RF ON
11:23 Problem at PA1 screen power supply
11:44 RF OFF (Radar school request)
12:27 RF ON
13:00 TX Power sample (-70 dB coupling)
Tx1 +6.6 dBm
Tx2 +1.6,3.6 dBm
Tx4 +1.4 dBm
Line voltage and power: 4100 VAC, 310 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +6.6 dBm
Tx2 +1.6,3.8 dBm
Tx4 +1.2 dBm
Line voltage and power: 4060 VAC, 300 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +6.6 dBm
Tx2 +1.6,3.7 dBm
Tx4 +1.4 dBm
Line voltage and power: 40100 VAC, 300 KW
15:17 RF OFF (Radar school request)
15:57 RF ON
17:00 TX Power sample (-70 dB coupling)
Tx1 +6.8 dBm
Tx2 +1.6,3.8 dBm
Tx4 +1.4 dBm
Line voltage and power: 4060 VAC, 300 KW
17:30 Driver 3 ON
18:00 TX Power sample (-70 dB coupling)
Tx1 +6.6 dBm
Tx2 +1.4 dBm
Tx4 +1.2 dBm
D3 -7.8 dBm
Line voltage and power: 4010 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +6.7 dBm
Tx2 +1.5 dBm
Tx4 +1.4 dBm
D3 -7.9 dBm
Line voltage and power: 4060 VAC, 300 KW

Change History (0)