Opened 9 years ago

#402 new Transmitters

20 Jul 19:00 Transmitter Power Measurement

Reported by: vquesada Owned by:
Priority: normal Milestone: 2015_07_2 Support ISR School
Component: ISR Version:
Keywords: Cc:

Description

14:35 LV ON
16:00 HV ON
16:05 TX Power sample (-70 dB coupling)
Tx1 +6.6 dBm
Tx2 +1.4,3.7 dBm
Tx4 +1.2 dBm
Line voltage and power: 4040 VAC, 310 KW
16:30 TX Power sample (-70 dB coupling)
Tx1 +6.6 dBm
Tx2 +1.4,3.5 dBm
Tx4 +1.2 dBm
Line voltage and power: 4040 VAC, 310 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +6.7 dBm
Tx2 +1.6 dBm
Tx4 +1.2 dBm
Line voltage and power: 4040 VAC, 310 KW
17:55 Driver3 ON
18:00 TX Power sample (-70 dB coupling)
Tx1 +6.7 dBm
Tx2 +1.6 dBm
Tx4 +1.2 dBm
D3 -9.2 dBm
Line voltage and power: 4080 VAC, 320 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +6.7 dBm
Tx2 +1.6 dBm
Tx4 +1.2 dBm
D3 -9.2 dBm
Line voltage and power: 4080 VAC, 320 KW

Change History (0)