09 Jul 19:30 Transmitter power measurements
Reported by: | ryaya | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2015_07 MST-ISR-EEJ |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
09:00 TX Power sample (-70 dB coupling)
Tx2 +3.7 dBm
Tx4 +3.8 dBm
Line voltage and power: 4100 VAC, 280 KW
10:00 TX Power sample (-70 dB coupling)
Tx2 +3.7 dBm
Tx4 +3.8 dBm
Line voltage and power: 4070 VAC, 280 KW
11:00 Problem with Driver 2 plate power supply, the output fuse blew up. The fuse was replaced and the operation continues
12:00 TX Power sample (-70 dB coupling)
Tx2 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4100 VAC, 280 KW
14:00 TX Power sample (-70 dB coupling)
Tx2 +3.7 dBm
Tx4 +3.8 dBm
Line voltage and power: 4040 VAC, 280 KW
15:00 TX Power sample (-70 dB coupling)
Tx2 +3.6 dBm
Tx4 +3.8 dBm
Line voltage and power: 4050 VAC, 280 KW
16:00 TX Power sample (-70 dB coupling)
Tx2 +3.7 dBm
Tx4 +3.8 dBm
Line voltage and power: 4060 VAC, 280 KW
17:00 Problem with the PA 2 screen power supply, some kind of arcing was detected at the switch yard, but nothing was found. Transmitter restarted operating normally.
18:00 TX Power sample (-70 dB coupling)
Tx2 +3.6 dBm
Tx4 +3.8 dBm
Line voltage and power: 4040 VAC, 280 KW
19:00 TX Power sample (-70 dB coupling)
Tx2 +3.7 dBm
Tx4 +3.8 dBm
Line voltage and power: 4070 VAC, 280 KW
Change History (1)
comment:1 Changed 9 years ago by ryaya
- Summary changed from 19:30 Transmitter power measurements to 09 Jul 19:30 Transmitter power measurements