﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
326	07 Jul 19:00 Transmitter Power Measurements	rtadeo		"09:00 LV ON (TR(s) are being used solid state.)
09:10 HV ON
10:40 TX Power sample (-70 dB coupling)
Tx2 +3.7 dBm
Tx4 +3.7 dBm
Line voltage and power: 4100 VAC, 285 KW
11:40 TX Power sample (-70 dB coupling)
Tx2 +3.9 dBm
Tx4 +3.7 dBm
Line voltage and power: 4100 VAC, 285 KW
13:40 TX Power sample (-70 dB coupling)
Tx2 +3.8 dBm
Tx4 +3.6 dBm
Line voltage and power: 4050 VAC, 280 KW
14:15  HV OFF (failure of the transmission line)
14:45  HV ON
14:45 TX Power sample (-70 dB coupling)
Tx2 +3.2 dBm
Tx4 +3.4 dBm
Line voltage and power: 4050 VAC, 280 KW
16:00 TX Power sample (-70 dB coupling)
Tx2 +3.7 dBm
Tx4 +3.2 dBm
Line voltage and power: 4050 VAC, 280 KW
17:00 TX Power sample (-70 dB coupling)
Tx2 +3.2 dBm
Tx4 +3.5 dBm
Line voltage and power: 4050 VAC, 280 KW
18:00 TX Power sample (-70 dB coupling)
Tx2 +3.3 dBm
Tx4 +3.5 dBm
Line voltage and power: 4050 VAC, 280 KW
19:00 TX Power sample (-70 dB coupling)
Tx2 +3.5 dBm
Tx4 +3.6 dBm
Line voltage and power: 4100 VAC, 285 KW
"	Transmitters	new	normal	2015_07 MST-ISR-EEJ	ISR			power	