Opened 10 years ago

#317 new Transmitters

11 Jun 19:00 Transmitter Power Measurements

Reported by: rtadeo Owned by:
Priority: normal Milestone: 2015_06 Valley Experiment
Component: ISR Version:
Keywords: Cc:

Description

08:00 TX Power sample (-70 dB coupling)
Tx2 +6.0 dBm
Tx4 +5.3 dBm
Line voltage and power: 4040 VAC, 330 KW
09:00 TX Power sample (-70 dB coupling)
Tx2 +6.0 dBm
Tx4 +5.3 dBm
Line voltage and power: 4040 VAC, 330 KW
10:00 TX Power sample (-70 dB coupling)
Tx2 +5.8 dBm
Tx4 +5.2 dBm
Line voltage and power: 4040 VAC, 330 KW
11:00 TX Power sample (-70 dB coupling)
Tx2 +5.7 dBm
Tx4 +5.2 dBm
Line voltage and power: 4040 VAC, 330 KW
12:00 TX Power sample (-70 dB coupling)
Tx2 +5.7 dBm
Tx4 +5.1 dBm
Line voltage and power: 4040 VAC, 330 KW
13:00 TX Power sample (-70 dB coupling)
Tx2 +5.7 dBm
Tx4 +5.1 dBm
Line voltage and power: 4040 VAC, 330 KW
14:00 TX Power sample (-70 dB coupling)
Tx2 +5.7 dBm
Tx4 +5.0 dBm
Line voltage and power: 4020 VAC, 330 KW
15:00 TX Power sample (-70 dB coupling)
Tx2 +5.7 dBm
Tx4 +5.0 dBm
Line voltage and power: 4020 VAC, 330 KW
16:00 TX Power sample (-70 dB coupling)
Tx2 +5.8 dBm
Tx4 +5.1 dBm
Line voltage and power: 4020 VAC, 330 KW
17:00 TX Power sample (-70 dB coupling)
Tx2 +6.0 dBm
Tx4 +5.2 dBm
Line voltage and power: 4080 VAC, 330 KW
18:00 TX Power sample (-70 dB coupling)
Tx2 +5.9 dBm
Tx4 +5.1 dBm
Line voltage and power: 4080 VAC, 330 KW
19:00 TX Power sample (-70 dB coupling)
Tx2 +5.8 dBm
Tx4 +5.1 dBm
Line voltage and power: 4060 VAC, 320 KW

Change History (0)

Note: See TracTickets for help on using tickets.