Opened 10 years ago
#309 new Transmitters
10 Jun 19:30 Transmitter power measurements
Reported by: | ryaya | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2015_06 Valley Experiment |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
08:10 LV ON
08:30 HV ON
10:00 TX Power sample (-70 dB coupling)
Tx2 +5.9 dBm
Tx4 +5.8 dBm
11:00 TX Power sample (-70 dB coupling)
Tx2 +6.0 dBm
Tx4 +5.8 dBm
Line voltage and power: 4040 VAC, 340 KW
12:00 TX Power sample (-70 dB coupling)
Tx2 +5.9 dBm
Tx4 +5.7 dBm
Line voltage and power: 4080 VAC, 340 KW
14:00 TX Power sample (-70 dB coupling)
Tx2 +5.8 dBm
Tx4 +5.6 dBm
Line voltage and power: 4020 VAC, 340 KW
15:00 TX Power sample (-70 dB coupling)
Tx2 +5.9 dBm
Tx4 +5.5 dBm
Line voltage and power: 4060 VAC, 350 KW
16:00 TX Power sample (-70 dB coupling)
Tx2 +5.8 dBm
Tx4 +5.4 dBm
Line voltage and power: 4030 VAC, 340 KW
17:00 TX Power sample (-70 dB coupling)
Tx2 +5.9 dBm
Tx4 +5.5 dBm
Line voltage and power: 4050 VAC, 340 KW
18:00 TX Power sample (-70 dB coupling)
Tx2 +5.9 dBm
Tx4 +5.5 dBm
Line voltage and power: 4040 VAC, 340 KW
19:00 TX Power sample (-70 dB coupling)
Tx2 +5.9 dBm
Tx4 +5.4 dBm
Line voltage and power: 4050 VAC, 340 KW