Opened 9 years ago

#228 new Transmitters

16 Apr 19:30 Transmitter power measurements

Reported by: ryaya Owned by:
Priority: normal Milestone: 2015_04_1 MST - ISR - EEJ
Component: ISR Version:
Keywords: Cc:

Description

09:00 TX Power sample (-70 dB coupling)
Tx1 +4.7 dBm
Tx2 +4.3 dBm
Line voltage and power: 4000 VAC, 300 Kw
10:00 TX Power sample (-70 dB coupling)
Tx1 +4.8 dBm
Tx2 +4.3 dBm
Line voltage and power: 4020 VAC, 300 Kw
11:00 TX Power sample (-70 dB coupling)
Tx1 +4.8 dBm
Tx2 +4.3 dBm
Line voltage and power: 4030 VAC, 300 Kw
12:00 TX Power sample (-70 dB coupling)
Tx1 +4.8 dBm
Tx2 +4.3 dBm
Line voltage and power: 4050 VAC, 300 Kw
14:00 TX Power sample (-70 dB coupling)
Tx1 +4.8 dBm
Tx2 +4.3 dBm
Line voltage and power: 4000 VAC, 300 Kw
15:00 TX Power sample (-70 dB coupling)
Tx1 +4.7 dBm
Tx2 +4.2 dBm
Line voltage and power: 3990 VAC, 300 Kw
15:25 Problem detected at Driver 4, disables PA 4 unit and PA 4 VACION pump failed. VACION replaced and transmitters works fine.
15:45 HV ON
16:00 TX Power sample (-70 dB coupling)
Tx1 +4.8 dBm
Tx2 +4.3 dBm
Line voltage and power: 4040 VAC, 300 Kw
17:00 TX Power sample (-70 dB coupling)
Tx1 +4.7 dBm
Tx2 +4.2 dBm
Line voltage and power: 4010 VAC, 300 Kw
18:00 TX Power sample (-70 dB coupling)
Tx1 +4.8 dBm
Tx2 +4.3 dBm
Line voltage and power: 4080 VAC, 300 Kw
19:00 TX Power sample (-70 dB coupling)
Tx1 +5.0 dBm
Tx2 +4.2 dBm
Line voltage and power: 4080 VAC, 300 Kw
19:20 CROWBAR alarm detected

Change History (0)

Note: See TracTickets for help on using tickets.