Opened 9 years ago

#218 new Transmitters

15 Apr 19:50 Transmitter power measurements

Reported by: ryaya Owned by:
Priority: normal Milestone: 2015_04_1 MST - ISR - EEJ
Component: ISR Version:
Keywords: Cc:

Description

09:00 TX Power sample (-70 dB coupling)
Tx1 +4.6 dBm
Tx2 +4.4 dBm
Line voltage and power: 4000 VAC, 300 Kw
10:00 TX Power sample (-70 dB coupling)
Tx1 +4.7 dBm
Tx2 +4.4 dBm
Line voltage and power: 4000 VAC, 300 Kw
11:08 Problem detected at 20 KV plate power supply. Limiter resistor failure at rectifier stage.
11:38 TX ON
12:00 TX Power sample (-70 dB coupling)
Tx1 +4.8 dBm
Tx2 +4.5 dBm
Line voltage and power: 4060 VAC, 310 Kw
14:00 TX Power sample (-70 dB coupling)
Tx1 +4.8 dBm
Tx2 +4.4 dBm
Line voltage and power: 4020 VAC, 300 Kw
15:00 TX Power sample (-70 dB coupling)
Tx1 +4.8 dBm
Tx2 +4.4 dBm
Line voltage and power: 4030 VAC, 310 Kw
16:00 RF OFF (HDD change at adquisition system)
17:00 TX Power sample (-70 dB coupling)
Tx1 +4.8 dBm
Tx2 +4.4 dBm
Line voltage and power: 4050 VAC, 310 Kw
18:00 TX Power sample (-70 dB coupling)
Tx1 +4.8 dBm
Tx2 +4.3 dBm
Line voltage and power: 4020 VAC, 300 Kw
19:00 TX Power sample (-70 dB coupling)
Tx1 +4.9 dBm
Tx2 +4.4 dBm
Line voltage and power: 4080 VAC, 310 Kw

Change History (0)

Note: See TracTickets for help on using tickets.