Opened 10 years ago
#200 new Transmitters
14 Apr 19:00 Transmitter Power Measurements
Reported by: | rtadeo | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2015_04_1 MST - ISR - EEJ |
Component: | ISR | Version: | |
Keywords: | power | Cc: |
Description
04/14/2015
MST - ISR - EEJ
06:40 LV ON
06:50 HV ON
07:00 TX Power sample (-70 dB coupling)
Tx2 +4.9 dBm
Tx4 +4.5 dBm
Line voltage and power: 4050 VAC, 300 Kw
08:00 TX Power sample (-70 dB coupling)
Tx2 +4.8 dBm
Tx4 +4.3 dBm
Line voltage and power: 4050 VAC, 300 Kw
09:00 TX Power sample (-70 dB coupling)
Tx2 +4.8 dBm
Tx4 +4.3 dBm
Line voltage and power: 4050 VAC, 300 Kw
10:00 TX Power sample (-70 dB coupling)
Tx2 +4.9 dBm
Tx4 +4.5 dBm
Line voltage and power: 4080 VAC, 300 Kw
11:00 TX Power sample (-70 dB coupling)
Tx2 +4.8 dBm
Tx4 +4.5 dBm
Line voltage and power: 4050 VAC, 300 Kw
12:00 TX Power sample (-70 dB coupling)
Tx2 +4.8 dBm
Tx4 +4.5 dBm
Line voltage and power: 4050 VAC, 300 Kw
13:00 TX Power sample (-70 dB coupling)
Tx2 +4.6 dBm
Tx4 +4.6 dBm
Line voltage and power: 4050 VAC, 300 Kw
14:00 TX Power sample (-70 dB coupling)
Tx2 +4.5 dBm
Tx4 +4.6 dBm
Line voltage and power: 4050 VAC, 300 Kw
15:00 TX Power sample (-70 dB coupling)
Tx2 +4.6 dBm
Tx4 +4.5 dBm
Line voltage and power: 4050 VAC, 300 Kw
16:00 TX Power sample (-70 dB coupling)
Tx2 +4.6 dBm
Tx4 +4.4 dBm
Line voltage and power: 4050 VAC, 300 Kw
17:00 TX Power sample (-70 dB coupling)
Tx2 +4.8 dBm
Tx4 +4.5 dBm
Line voltage and power: 4070 VAC, 300 Kw
18:00 TX Power sample (-70 dB coupling)
Tx2 +4.8 dBm
Tx4 +4.5 dBm
Line voltage and power: 4080 VAC, 300 Kw
19:00 TX Power sample (-70 dB coupling)
Tx2 +4.8 dBm
Tx4 +4.5 dBm