00:00 TX Power sample (-70 dB coupling)
Tx1 +2.6 dBm
Tx3 +6.4 dBm
Tx4 +2.6 dBm
D2 -6.9 dBm
Line voltage and power: 4050 VAC, 280 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +2.6 dBm
Tx3 +6.4 dBm
Tx4 +2.6 dBm
D2 -6.9 dBm
Line voltage and power: 4050 VAC, 280 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +2.6 dBm
Tx3 +6.4 dBm
Tx4 +2.6 dBm
D2 -6.9 dBm
Line voltage and power: 4050 VAC, 280 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +2.6 dBm
Tx3 +6.4 dBm
Tx4 +2.6 dBm
D2 -6.9 dBm
Line voltage and power: 4050 VAC, 280 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +2.6 dBm
Tx3 +6.4 dBm
Tx4 +2.6 dBm
D2 -6.9 dBm
Line voltage and power: 4050 VAC, 280 KW
04:45 Crowbar
05:00 TX Power sample (-70 dB coupling)
Tx1 +2.5 dBm
Tx3 +6.5 dBm
Tx4 +2.6 dBm
D2 -6.9 dBm
Line voltage and power: 4070 VAC, 280 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +2.5 dBm
Tx3 +6.5 dBm
Tx4 +2.6 dBm
D2 -6.9 dBm
Line voltage and power: 4070 VAC, 280 KW
06:55 Driver 2 OFF
07:00 TX Power sample (-70 dB coupling)
Tx1 +2.5 dBm
Tx3 +6.5 dBm
Tx4 +2.6/5.0 dBm
Line voltage and power: 4070 VAC, 280 KW

Change History (0)

Note: See TracTickets for help on using tickets.