﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1792	18 Dec 20:00 Transmitter Power Measurements	vquesada		"20:00 TX Power sample (-70 dB coupling)
Tx1 +2.5 dBm
Tx3 +6.2 dBm
Tx4 +2.6 dBm
D2 -7.0 dBm
Line voltage and power: 4040 VAC, 280 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +2.5 dBm
Tx3 +6.2 dBm
Tx4 +2.6 dBm
D2 -7.0 dBm
Line voltage and power: 4040 VAC, 280 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +2.5 dBm
Tx3 +6.2 dBm
Tx4 +2.6 dBm
D2 -7.0 dBm
Line voltage and power: 4040 VAC, 280 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +2.5 dBm
Tx3 +6.2 dBm
Tx4 +2.6 dBm
D2 -7.0 dBm
Line voltage and power: 4040 VAC, 280 KW"	Transmitters	new	normal	2017_12 Convection Polar Cap	ISR	JRO Staff			