Opened 7 years ago

#1766 new Transmitters

16 Dec 19:00 Transmitter Power Measurements

Reported by: vquesada Owned by:
Priority: normal Milestone: 2017_12 Convection Polar Cap
Component: ISR Version:
Keywords: Cc:

Description

06:54 LV ON
07:07 HV ON
07:45 TX Power sample (-70 dB coupling)
Tx1 +2.7 dBm
Tx3 +6.4 dBm
Tx4 +2.7/5.0 dBm
Line voltage and power: 4040 VAC, 280 KW
08:30 TX Power sample (-70 dB coupling)
Tx1 +2.8 dBm
Tx3 +6.5 dBm
Tx4 +2.7/5.0 dBm
Line voltage and power: 4040 VAC, 280 KW
09:00 TX Power sample (-70 dB coupling)
Tx1 +2.8 dBm
Tx3 +6.5 dBm
Tx4 +2.7/5.0 dBm
Line voltage and power: 4040 VAC, 280 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 +2.8 dBm
Tx3 +6.5 dBm
Tx4 +2.7/5.0 dBm
Line voltage and power: 4040 VAC, 280 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 +2.8 dBm
Tx3 +6.5 dBm
Tx4 +2.7/5.0 dBm
Line voltage and power: 4040 VAC, 280 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 +2.8 dBm
Tx3 +6.5 dBm
Tx4 +2.7/5.0 dBm
Line voltage and power: 4040 VAC, 280 KW
12:15 RF control fails
13:00 TX Power sample (-70 dB coupling)
Tx1 +2.7 dBm
Tx3 +6.5 dBm
Tx4 +2.7/5.0 dBm
Line voltage and power: 4040 VAC, 280 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +2.7 dBm
Tx3 +6.5 dBm
Tx4 +2.7/5.0 dBm
Line voltage and power: 4040 VAC, 280 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +2.7 dBm
Tx3 +6.5 dBm
Tx4 +2.7/5.0 dBm
Line voltage and power: 4040 VAC, 280 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +2.9 dBm
Tx3 +6.5 dBm
Tx4 +2.7/5.2 dBm
Line voltage and power: 4040 VAC, 280 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +2.9 dBm
Tx3 +6.5 dBm
Tx4 +2.7/5.2 dBm
Line voltage and power: 4040 VAC, 280 KW
17:28 Overcurrent in the Tx3 screen source
18:06 Txs Ok.
18:10 TX Power sample (-70 dB coupling)
Tx1 +2.8 dBm
Tx3 +6.4 dBm
Tx4 +2.8 dBm
D2 -7.1 dBm
Line voltage and power: 4040 VAC, 280 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +2.8 dBm
Tx3 +6.4 dBm
Tx4 +2.8 dBm
D2 -7.1 dBm

Change History (0)

Note: See TracTickets for help on using tickets.