1727	27 Sept 19:30 Transmitter report	ryaya		"09:00 Power sample (-70 dB coupling)
D2 -5.0 dBm
D4 -5.0 dBm
Line Voltage and Power: 4130 VAC
10:00 Power sample (-70 dB coupling)
D2 -5.0 dBm
D4 -5.0 dBm
Line Voltage and Power: 4100 VAC
11:00 Power sample (-70 dB coupling)
D2 -5.0 dBm
D4 -5.0 dBm
Line Voltage and Power: 4130 VAC
12:00 Power sample (-70 dB coupling)
D2 -5.1 dBm
D4 -5.2 dBm
14:00 Power sample (-70 dB coupling)
D2 -5.2 dBm
D4 -5.2 dBm
Line Voltage and Power: 4100 VAC
15:00 Power sample (-70 dB coupling)
D2 -5.2 dBm
D4 -5.2 dBm
16:00 Power sample (-70 dB coupling)
D2 -5.2 dBm
D4 -5.2 dBm
Line Voltage and Power: 4100 VAC
17:00 Power sample (-70 dB coupling)
D2 -5.1 dBm
D4 -5.1 dBm
17:20 D1 ON ""IMAGING""
18:00 Power sample (-70 dB coupling)
D1 -8.3 dBm
D2 -5.0 dBm
D4 -5.0 dBm
Line Voltage and Power: 4120 VAC
19:00 Power sample (-70 dB coupling)
D1 -8.2 dBm
D2 -5.0 dBm
D4 -5.0 dBm
"	Transmitters	new	normal	2017_09_02 Drifts Meduim Power	ISR				