Opened 7 years ago

#1710 new Transmitters

20 Set 23:00 Transmitter Power Measurements

Reported by: vquesada Owned by:
Priority: normal Milestone: 2017_09_01 Meteors
Component: ISR Version:
Keywords: Cc:

Description

17:00 LV
17:30 HV
17:30 Power sample (-70 dB coupling)
Tx1 +3.0 dBm
Line Voltage and Power: 4060 VAC, 200 KW
17:33 Drops screen power supply Tx1
17:57 Drops screen power supply Tx1
18:03 Crowbar Drops HV power supply
18:05 Power sample (-70 dB coupling)
Tx1 +2.9 dBm
Line Voltage and Power: 4060 VAC, 200 KW
19:00 Power sample (-70 dB coupling)
Tx1 +2.9 dBm
Line Voltage and Power: 4100 VAC, 200 KW
20:00 Power sample (-70 dB coupling)
Tx1 +2.8 dBm
Line Voltage and Power: 4100 VAC, 200 KW
21:00 Power sample (-70 dB coupling)
Tx1 +2.8 dBm
Line Voltage and Power: 4100 VAC, 200 KW
22:00 Power sample (-70 dB coupling)
Tx1 +2.9 dBm
Line Voltage and Power: 4100 VAC, 200 KW
23:00 Power sample (-70 dB coupling)
Tx1 +2.9 dBm
Line Voltage and Power: 4100 VAC, 200 KW

Change History (0)

Note: See TracTickets for help on using tickets.