Opened 9 years ago

#155 new Transmitters

26 Mar 07:30 Transmitter Power measurements

Reported by: rtadeo Owned by:
Priority: normal Milestone: 2015_03 ISR + Imaging CNOFS Support
Component: ISR+Imaging Version:
Keywords: Cc:

Description

25/03/2015

20:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.2 dBm
Tx4 +2.3 dBm
Dr3 -5.6 dBm
Line voltage and power: 4050 VAC, 300 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.2 dBm
Tx4 +2.3 dBm
Dr3 -5.6 dBm
Line voltage and power: 4050 VAC, 300 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.3 dBm
Tx4 +2.3 dBm
Dr3 -5.7 dBm
Line voltage and power: 4050 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.3 dBm
Tx4 +2.3 dBm
Dr3 -5.7 dBm
Line voltage and power: 4050 VAC, 300 KW

26/03/2015

00:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.3 dBm
Tx4 +2.3 dBm
Dr3 -5.7 dBm
Line voltage and power: 4100 VAC, 310 KW
00:55 Drv3 OFF (IMAGING)
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.4 dBm/+5.6 dBm
Tx4 +2.4 dBm
Dr3 off
Line voltage and power: 4100 VAC, 305 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.4 dBm/+5.6 dBm
Tx4 +2.4 dBm
Dr3 off
Line voltage and power: 4100 VAC, 305 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.3 dBm/+5.7 dBm
Tx4 +2.3 dBm
Dr3 off
Line voltage and power: 4050 VAC, 300 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.3 dBm/+5.7 dBm
Tx4 +2.3 dBm
Dr3 off
Line voltage and power: 4050 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.6 dBm/+5.7 dBm
Tx4 +2.4 dBm
Dr3 off
Line voltage and power: 4100 VAC, 300 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.6 dBm/+5.7 dBm
Tx4 +2.4 dBm
Dr3 off
Line voltage and power: 4100 VAC, 300 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.6 dBm/+5.7 dBm
Tx4 +2.4 dBm
Dr3 off
Line voltage and power: 4100 VAC, 300 KW

Change History (0)