Opened 10 years ago
#2054 new Transmitters
07 Jan 19:25 Transmitter power measurements
Reported by: | ryaya | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2015_01 MST+ISR+EEJ |
Component: | ISR | Version: | |
Keywords: | Cc: | ||
Parent Tickets: |
Description
09:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4040 VAC, 280 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4040 VAC, 280 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.8 dBm
Line voltage and power: 4060 VAC, 280 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.7 dBm
Line voltage and power: 4050 VAC, 280 KW
13:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4080 VAC, 280 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4070 VAC, 280 KW
14:02 Problem detected at PA 1 screen power supply
15:00 TX Power sample (-70 dB coupling)
Tx1 +3.7 dBm
Tx4 +3.6 dBm
Line voltage and power: 4000 VAC, 280 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +3.7 dBm
Tx4 +3.8 dBm
Line voltage and power: 4040 VAC, 280 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4090 VAC, 290 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4060 VAC, 280 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +3.9 dBm
Line voltage and power: 4100 VAC, 290 KW