16 Jan 19:20 Transmitter power measurements
Reported by: | ryaya | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2015_01 MST+ISR+EEJ |
Component: | ISR | Version: | |
Keywords: | Cc: | ||
Parent Tickets: |
Description
06:40 LV ON
06:50 HV ON
07:06 CROWBAR Main plate voltage failure
08:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4070 VAC, 280 KW
09:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4020 VAC, 280 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4060 VAC, 280 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4060 VAC, 280 KW
11:57 Problem on PLC system causes an interruption on transmitter system, a system restarting was required
12:30 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4060 VAC, 280 KW
12:40 CROWBAR main plate voltage failure
13:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4080 VAC, 280 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4080 VAC, 280 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4050 VAC, 280 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4080 VAC, 280 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4030 VAC, 280 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4080 VAC, 280 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4100 VAC, 290 KW