#2027 new Transmitters
21 Dec 19:30 Transmitter power measurements
Reported by: | ryaya | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2014_12 ISCOD Northern Deeper Winter Dic 15-22 |
Component: | ISR | Version: | |
Keywords: | Cc: | ||
Parent Tickets: |
Description
09:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.3 dBm
Voltage line and power: 4070 VAC, 300 KW
10:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.5 dBm
4 +2.2 dBm
Voltage line and power: 4080 VAC, 300 KW
11:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.1 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4080 VAC, 300 KW
12:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4100 VAC, 300 KW
13:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +1.9 dBm/ +5.4 dBm
4 +2.3 dBm
Voltage line and power: 4080 VAC, 300 KW
14:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.4 dBm
Voltage line and power: 4090 VAC, 300 KW
15:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4090 VAC, 300 KW
16:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +1.9 dBm/ +5.4 dBm
4 +2.3 dBm
Voltage line and power: 4020 VAC, 290 KW
16:08 Problem at main voltage source causes the systemo goes off for some minutes.
17:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4030 VAC, 300 KW
17:40 Driver 3 ON (IMAGING)
18:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm
4 +2.3 dBm
D3 -5.6 dBm
Voltage line and power: 4020 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm
4 +2.4 dBm
D3 -5.6 dBm
Voltage line and power: 4030 VAC, 290 KW
18:40 Problem detected at PA 4 screen power supply.