﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc	parents
2013	20 Dec 19:30 Transmitter power measurements	ryaya		"09:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.3 dBm
Voltage line and power: 4040 VAC, 290 KW
10:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.5 dBm
4 +2.3 dBm
Voltage line and power: 4020 VAC, 290 KW 
11:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.2 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4080 VAC, 300 KW
12:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.2 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4100 VAC, 300 KW
13:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.2 dBm/ +5.4 dBm
4 +2.4 dBm
Voltage line and power: 4090 VAC, 300 KW
14:00 TX Power sample (-70 dB coupling)
1 +5.5 dBm
2 +2.1 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4040 VAC, 300 KW
15:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.5 dBm
4 +2.4 dBm
16:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.6 dBm
4 +2.4 dBm
Voltage line and power: 4040 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.6 dBm
4 +2.4 dBm
Voltage line and power: 4020 VAC, 290 KW
17:30 Driver 3 ON (IMAGING)
18:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.2 dBm
4 +2.4 dBm
D3 -5.7 dBm
Voltage line and power: 4050 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.1 dBm
4 +2.5 dBm
D3 -5.6 dBm