Opened 10 years ago

#2005 new Transmitters

20 Dec 07:50 Transmitter power measurements

Reported by: rtadeo Owned by:
Priority: normal Milestone: 2014_12 ISCOD Northern Deeper Winter Dic 15-22
Component: ISR+Imaging Version:
Keywords: Cc:
Parent Tickets:

Description

20:00 TX Power sample (-70 dB coupling)

Tx1 +5.4 dBm
Tx2 +2.0 dBm
Tx4 +2.4 dBm
Dr3 -5.6 dBm
Voltage line and power: 4050 VAC, 300 KW

21:00 TX Power sample (-70 dB coupling)

Tx1 +5.3 dBm
Tx2 +1.8 dBm
Tx4 +2.4 dBm
Dr3 -5.7 dBm
Voltage line and power: 4050 VAC, 300 KW

22:00 TX Power sample (-70 dB coupling)

Tx1 +5.3 dBm
Tx2 +1.8 dBm
Tx4 +2.4 dBm
Dr3 -5.7 dBm
Voltage line and power: 4050 VAC, 300 KW

23:00 TX Power sample (-70 dB coupling)

Tx1 +5.3 dBm
Tx2 +1.9 dBm
Tx4 +2.4 dBm
Dr3 -5.7 dBm
Voltage line and power: 4060 VAC, 300 KW

00:00 TX Power sample (-70 dB coupling)

Tx1 +5.3 dBm
Tx2 +1.9 dBm
Tx4 +2.4 dBm
Dr3 -5.7 dBm
Voltage line and power: 4050 VAC, 300 KW

01:00 TX Power sample (-70 dB coupling)

Tx1 +5.2 dBm
Tx2 +1.8 dBm / +5.5 dBm
Tx4 +2.4 dBm
Dr3 OFF
Voltage line and power: 4020 VAC, 290 KW

02:00 TX Power sample (-70 dB coupling)

Tx1 +5.2 dBm
Tx2 +1.8 dBm / +5.5 dBm
Tx4 +2.4 dBm
Dr3 OFF
Voltage line and power: 4020 VAC, 290 KW

03:00 TX Power sample (-70 dB coupling)

Tx1 +5.2 dBm
Tx2 +1.8 dBm / +5.5 dBm
Tx4 +2.4 dBm
Dr3 OFF
Voltage line and power: 4020 VAC, 290 KW

04:00 TX Power sample (-70 dB coupling)

Tx1 +5.2 dBm
Tx2 +1.8 dBm / +5.5 dBm
Tx4 +2.4 dBm
Dr3 OFF
Voltage line and power: 4050 VAC, 300 KW

05:00 TX Power sample (-70 dB coupling)

Tx1 +5.2 dBm
Tx2 +1.8 dBm / +5.3 dBm
Tx4 +2.2 dBm
Dr3 OFF
Voltage line and power: 4050 VAC, 300 KW

06:00 TX Power sample (-70 dB coupling)

Tx1 +5.2 dBm
Tx2 +1.8 dBm / +5.3 dBm
Tx4 +2.2 dBm
Dr3 OFF
Voltage line and power: 4050 VAC, 300 KW

07:00 TX Power sample (-70 dB coupling)

Tx1 +5.2 dBm
Tx2 +1.8 dBm / +5.3 dBm
Tx4 +2.2 dBm
Dr3 OFF
Voltage line and power: 4050 VAC, 300 KW