Opened 10 years ago
#2005 new Transmitters
20 Dec 07:50 Transmitter power measurements
Reported by: | rtadeo | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2014_12 ISCOD Northern Deeper Winter Dic 15-22 |
Component: | ISR+Imaging | Version: | |
Keywords: | Cc: | ||
Parent Tickets: |
Description
20:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.0 dBm
Tx4 +2.4 dBm
Dr3 -5.6 dBm
Voltage line and power: 4050 VAC, 300 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +1.8 dBm
Tx4 +2.4 dBm
Dr3 -5.7 dBm
Voltage line and power: 4050 VAC, 300 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +1.8 dBm
Tx4 +2.4 dBm
Dr3 -5.7 dBm
Voltage line and power: 4050 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +1.9 dBm
Tx4 +2.4 dBm
Dr3 -5.7 dBm
Voltage line and power: 4060 VAC, 300 KW
00:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +1.9 dBm
Tx4 +2.4 dBm
Dr3 -5.7 dBm
Voltage line and power: 4050 VAC, 300 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +1.8 dBm / +5.5 dBm
Tx4 +2.4 dBm
Dr3 OFF
Voltage line and power: 4020 VAC, 290 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +1.8 dBm / +5.5 dBm
Tx4 +2.4 dBm
Dr3 OFF
Voltage line and power: 4020 VAC, 290 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +1.8 dBm / +5.5 dBm
Tx4 +2.4 dBm
Dr3 OFF
Voltage line and power: 4020 VAC, 290 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +1.8 dBm / +5.5 dBm
Tx4 +2.4 dBm
Dr3 OFF
Voltage line and power: 4050 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +1.8 dBm / +5.3 dBm
Tx4 +2.2 dBm
Dr3 OFF
Voltage line and power: 4050 VAC, 300 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +1.8 dBm / +5.3 dBm
Tx4 +2.2 dBm
Dr3 OFF
Voltage line and power: 4050 VAC, 300 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +1.8 dBm / +5.3 dBm
Tx4 +2.2 dBm
Dr3 OFF
Voltage line and power: 4050 VAC, 300 KW