Opened 10 years ago

#1982 new Transmitters

19 Dec. 07:00 Transmitter Power Measurements

Reported by: vquesada Owned by:
Priority: normal Milestone: 2014_12 ISCOD Northern Deeper Winter Dic 15-22
Component: ISR Version:
Keywords: Cc:
Parent Tickets:

Description

19 December 2014
00:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.2 dBm
Tx4 +2.7 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 300 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.2 dBm
Tx4 +2.7 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 300 KW

02:00 Driver 3 OFF

02:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.1,5.4 dBm
Tx4 +2.7 dBm
D3 -5.5 dBm
Line voltage and power: 4080 VAC, 300 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.1,5.4 dBm
Tx4 +2.7 dBm
D3 -5.5 dBm
Line voltage and power: 4080 VAC, 300 KW

03:10 a 03:17 crowbar por caida de tension

04:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.3,5.7 dBm
Tx4 +2.5 dBm
Line voltage and power: 4080 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.3,5.7 dBm
Tx4 +2.5 dBm
Line voltage and power: 4080 VAC, 300 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.5,5.8 dBm
Tx4 +2.7 dBm
Line voltage and power: 4100 VAC, 310 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.5,5.8 dBm
Tx4 +2.7 dBm
Line voltage and power: 4100 VAC, 310 KW.