Opened 10 years ago
#1934 new Transmitters
17 Dec 19:30 Transmitter power measurements
Reported by: | ryaya | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2014_12 ISCOD Northern Deeper Winter Dic 15-22 |
Component: | ISR | Version: | |
Keywords: | Cc: | ||
Parent Tickets: |
Description
09:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.5 dBm
Voltage line and power: 4060 VAC, 300 KW
10:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.3 dBm
4 +2.5 dBm
Voltage line and power: 4060 VAC, 300 KW
11:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +1.9 dBm/ +5.3 dBm
4 +2.3 dBm
Voltage line and power: 4060 VAC, 290 KW
12:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.5 dBm
Voltage line and power: 4060 VAC, 290 KW
13:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.3 dBm
4 +2.5 dBm
Voltage line and power: 4060 VAC, 290 KW
14:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.5 dBm
14:05 Problem detected at PA1 screen power supply
15:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.1 dBm/ +5.4 dBm
4 +2.6 dBm
Voltage line and power: 4090 VAC, 300 KW
16:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.4 dBm
Voltage line and power: 4020 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.3 dBm
4 +2.5 dBm
Voltage line and power: 4100 VAC, 300 KW
17:30 Driver 3 ON (IMAGING)
18:00 TX Power sample (-70 dB coupling)
1 +5.5 dBm
2 +2.0 dBm
4 +2.5 dBm
D3 -5.6 dBm
Voltage line and power: 4080 VAC, 290 KW
19:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm
4 +2.4 dBm
D3 -5.7 dBm
Voltage line and power: 4080 VAC, 290 KW