Opened 10 years ago

Last modified 10 years ago

#1878 new Transmitters

28 Nov 07:10 Transmitter Power Measurements — at Version 1

Reported by: vquesada Owned by:
Priority: normal Milestone: 2014_11 ISR + Imaging Nov 24-28
Component: ISR Version:
Keywords: Cc:
Parent Tickets:

Description (last modified by ryanque)

28 November 2014
00:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.2 dBm
Tx4 +2.1 dBm
D3 -5.8 dBm
Line voltage and power: 4080 VAC, 300 KW
Temp HP: 81 ºF, LP: 80 ºF
01:00 RF Driver 4 OFF
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2,5.5 dBm
Tx4 +2.1 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 80 ºF, LP: 79 ºF
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2,5.5 dBm
Tx4 +2.1 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 80 ºF, LP: 79 ºF
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2,5.5 dBm
Tx4 +2.1 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 80 ºF, LP: 79 º
03:20 Crowbar por caida de tensio
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.5,5.6 dBm
Tx4 +2.3 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 78 ºF, LP: 77 ºF
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.5,5.6 dBm
Tx4 +2.3 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 78 ºF, LP: 77 ºF
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.4,5.6 dBm
Tx4 +2.5 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 78 ºF, LP: 77 ºF
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.4,5.6 dBm
Tx4 +2.5 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 78 ºF, LP: 77 ºF

Subtickets (add)

Change History (1)

comment:1 Changed 10 years ago by ryanque

  • Description modified (diff)
Note: See TracTickets for help on using tickets.