Opened 10 years ago
#1876 new Transmitters
27 Nov 19:15 Transmitter Power Measurements
Reported by: | rtadeo | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2014_11 ISR + Imaging Nov 24-28 |
Component: | ISR+Imaging | Version: | |
Keywords: | Cc: | ||
Parent Tickets: |
Description
2014_11 ISR + Imaging Nov 24-28
27 November 2014
08:00 TX Power sample (-70 dB coupling)
Tx1 +5.1 dBm
Tx2 +2.2/+5.1 dBm
Tx4 +2.4 dBm
D3 RF (Off)
Line voltage and power: 4080 VAC, 300 KW
08:36 RF OFF Cooling system failure
10:48 TX Power sample (-70 dB coupling)
Tx1 +5.1 dBm
Tx2 +2.2/+5.1 dBm
Tx4 +2.0 dBm
D3 RF (Off)
Line voltage and power: 4060 VAC, 280 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 +5.0 dBm
Tx2 +1.9/+5.2 dBm
Tx4 +2.0 dBm
D3 RF (Off)
Line voltage and power: 4060 VAC, 280 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +5.1 dBm
Tx2 +2.2/+5.1 dBm
Tx4 +2.0 dBm
D3 RF (Off)
Line voltage and power: 4000 VAC, 280 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.0/+5.1 dBm
Tx4 +2.1 dBm
D3 RF (Off)
Line voltage and power: 4100 VAC, 290 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.2/+5.5 dBm
Tx4 +2.2 dBm
D3 RF (Off)
Line voltage and power: 4100 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.2/+5.5 dBm
Tx4 +2.2 dBm
D3 RF (Off)
Line voltage and power: 4100 VAC, 300 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2 dBm
Tx4 +2.1 dBm
D3 -5.6 dBm
Line voltage and power: 4000 VAC, 290 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2 dBm
Tx4 +2.1 dBm
D3 -5.6 dBm
Line voltage and power: 4000 VAC, 290 KW