﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc	parents
1867	27 Nov 07:08 Transmitter Power Measurements	vquesada		"'''27 November 2014'''
00:00 TX Power sample (-70 dB coupling)
Tx1 +5.1 dBm
Tx2 +2.4 dBm
Tx4 +2.4 dBm
D3 -5.6 dBm
Line voltage and power: 4050 VAC, 300 KW
00:10 TX Power sample (-70 dB coupling)
Tx1 +5.1 dBm
Tx2 +2.3,5.5 dBm
Tx4 +2.4 dBm
Line voltage and power: 4050 VAC, 300 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.3,5.5 dBm
Tx4 +2.4 dBm
Line voltage and power: 4080 VAC, 300 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.3,5.5 dBm
Tx4 +2.4 dBm
Line voltage and power: 4080 VAC, 300 KW
02:42 Falla 1ntercambiador 1 se rompe eje.
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.3,5.4 dBm
Tx4 +2.4 dBm
Line voltage and power: 4100 VAC, 300 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.3,5.4 dBm
Tx4 +2.4 dBm
Line voltage and power: 4100 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.3,5.4 dBm
Tx4 +2.4 dBm
Line voltage and power: 4100 VAC, 300 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2,5.4 dBm
Tx4 +2.4 dBm
Line voltage and power: 4100 VAC, 300 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2,5.4 dBm
Tx4 +2.4 dBm
Line voltage and power: 4100 VAC, 300 Kw"	Transmitters	new	normal	2014_11 ISR + Imaging Nov 24-28	ISR					