#1839 new Transmitters
24 Nov 19:30 Transmitter Power Measurements
Reported by: | rtadeo | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2014_11 ISR + Imaging Nov 24-28 |
Component: | ISR+Imaging | Version: | |
Keywords: | Cc: | ||
Parent Tickets: |
Description
24 November 2014
20:50 Failure by variation of AC line
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2 dBm
Tx4 +2.2 dBm
Drv3-5.8 dBm
Line voltage and power: 4050 VAC, 300 KW
21:25 TX Failure by variation of AC line
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.2 dBm
Tx4 +2.3 dBm
D3 -5.6 dbm
Line voltage and power: 4100 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.2 dBm
Tx4 +2.3 dBm
D3 -5.6 dbm
Line voltage and power: 4100 VAC, 300 KW
25 November 2014
00:30 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.5 dBm /+5.9 dBm
Tx4 +2.3 dBm
D3 RF off
Line voltage and power: 4100 VAC, 310 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.5 dBm /+5.8 dBm
Tx4 +2.3 dBm
D3 RF off
Line voltage and power: 4100 VAC, 300 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.5 dBm /+5.8 dBm
Tx4 +2.3 dBm
D3 RF off
Line voltage and power: 4100 VAC, 300 KW
00:20 fails PA 4
00:50 fails PA 4
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.3 dBm /+5.5 dBm
Tx4 +2.3 dBm
D3 RF off
Line voltage and power: 4070 VAC, 295 KW
03:25 fails PA 4
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2 dBm /+5.5 dBm
Tx4 +2.2 dBm
D3 RF off
Line voltage and power: 4070 VAC, 295 KW
04:05 fails PA 4
04:25 fails PA 4
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2 dBm /+5.5 dBm
Tx4 +2.2 dBm
D3 RF off
Line voltage and power: 4050 VAC, 290 KW
05:30 fails PA 4
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2 dBm /+5.5 dBm
Tx4 +2.2 dBm
D3 RF off
Line voltage and power: 4050 VAC, 290 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.1 dBm /+5.4 dBm
Tx4 +2.0 dBm
D3 RF off
Line voltage and power: 4100 VAC, 300 KW
07:00 fails PA 4
07:05 fails PA 4
Subtickets (add)
Change History (1)
comment:1 Changed 10 years ago by imanay
- Summary changed from 24 November 19:30 Transmitter Power Measurements to 24 Nov 19:30 Transmitter Power Measurements