Opened 10 years ago
#1803 new Transmitters
02 Oct. 19:00 Transmitter Power Measurements
Reported by: | rtadeo | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2014_09 MST + ISR + EEJ |
Component: | ISR | Version: | |
Keywords: | power | Cc: | |
Parent Tickets: |
Description
02 - 10 - 2014
08:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.9 dBm
Line voltage and power: 4100 VAC, 300 KW
09:00 TX Power sample (-70 dB coupling)
Tx1 +3.7 dBm
Tx4 +3.9 dBm
Line voltage and power: 4100 VAC, 300 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4050 VAC, 300 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 +3.6 dBm
Tx4 +3.6 dBm
Line voltage and power: 4000 VAC, 290 KW
11:25 Falla Crowbar H.V. variation in AC line
11:47 Falla Crowbar H.V. variation in AC line
12:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +4.0 dBm
Line voltage and power: 4100 VAC, 300 KW
13:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
14:00 TX Power sample (-70 dB coupling)
Tx1 +3.6 dBm
Tx4 +3.8 dBm
Line voltage and power: 4010 VAC, 290 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.6 dBm
16:00 TX Power sample (-70 dB coupling)
Tx1 +3.6 dBm
Tx4 +3.8 dBm
17:00 TX Power sample (-70 dB coupling)
Tx1 +3.7 dBm
Tx4 +4.0 dBm
18:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 300 KW