Opened 10 years ago

#1792 new Transmitters

01 October 23:10 Transmitter Power Measurements

Reported by: vquesada Owned by:
Priority: normal Milestone: 2014_09 MST + ISR + EEJ
Component: ISR Version:
Keywords: Cc:
Parent Tickets:

Description

01 october 2013
20:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.0 dBm
Line voltage and power: 4050 VAC, 300 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.0 dBm
Line voltage and power: 4050 VAC, 300 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4100 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4100 VAC, 300 KW

Subtickets (add)

Change History (0)

Note: See TracTickets for help on using tickets.