1791	1 Oct 19:45 Transmitter power measurements	ryaya		"09:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4070 VAC, 290 KW
09:20 Phase adjustment on PA 1.
10:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.9 dBm
Line voltage and power: 4020 VAC, 290 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 +3.6 dBm
Tx4 +3.7 dBm
Line voltage and power: 4000 VAC, 290 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 290 KW
13:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.9 dBm
Line voltage and power: 4060 VAC, 290 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +4.0 dBm
Line voltage and power: 4040 VAC, 290 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.9 dBm
Line voltage and power: 4060 VAC, 290 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4080 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +4.0 dBm
Line voltage and power: 4040 VAC, 290 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4080 VAC, 290 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4120 VAC, 300 KW
"	Transmitters	new	normal	2014_09 MST + ISR + EEJ	ISR					