Opened 10 years ago

#1709 new Transmitters

23 Sep 19:50 Transmitter Power measurements

Reported by: ryaya Owned by:
Priority: normal Milestone: 2014_09 ISR + Imaging
Component: ISR Version:
Keywords: Cc:
Parent Tickets:

Description

9:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.2 dBm/ +5.6 dBm
4 +1.9 dBm
Voltage line and power: 4070 VAC, 305 KW
10:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.3 dBm/ +5.6 dBm
4 +2.0 dBm
Voltage line and power: 4000 VAC, 305 KW
10:56 Alarm detected at Screen power supply PA 1
11:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.3 dBm/ +5.8 dBm
4 +2.2 dBm
Voltage line and power: 4020 VAC, 310 KW
12:00 Alarm detected at Screen power supply PA 2
12:05 TX Power sample (-70 dB coupling)
1 +5.7 dBm
2 +2.4 dBm/ +5.6 dBm
4 +2.0 dBm
Voltage line and power: 4080 VAC, 315 KW
13:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.0 dBm/ +5.4 dBm
4 +1.8 dBm
Voltage line and power: 4000 VAC, 300 KW
13:40 Alarm detected at screen power supply PA 2
14:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.1 dBm/ +5.2 dBm
4 +1.8 dBm
Voltage line and power: 4020 VAC, 305 KW
15:00 TX Power sample (-70 dB coupling)
1 +5.5 dBm
2 +2.2 dBm/ +5.3 dBm
4 +2.0 dBm
Voltage line and power: 4030 VAC, 305 KW
16:00 TX Power sample (-70 dB coupling)
1 +5.5 dBm
2 +2.2 dBm/ +5.2 dBm
4 +2.0 dBm
Voltage line and power: 4080 VAC, 310 KW
17:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.4 dBm/ +5.6 dBm
4 +2.1 dBm
Voltage line and power: 4080 VAC, 310 KW

18:00 TX Power sample (-70 dB coupling)
1 +5.8 dBm
2 +2.3 dBm
4 +2.0 dBm
D3 -5.4 dBm
Voltage line and power: 4030 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.4 dBm
4 +2.1 dBm
D3 -5.5 dBm
Voltage line and power: 4100 VAC, 305 KW