1556	09 May 08:00 Transmitter Power mesearuments	rtadeo		"08/05/2007
20:00 TX Power sample (-70 dB coupling)
 Tx1 +6.2 dBm
 Tx2 +2.2 dBm
 Tx4 +2.2 dBm
 Dv3 -6.5 dBm
 Line voltage and power: 4050 VAC, 310 KW
21:00 TX Power sample (-70 dB coupling)
 Tx1 +6.2 dBm
 Tx2 +2.2 dBm
 Tx4 +2.2 dBm
 Dv3 -6.5 dBm
22:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.0 dBm
 Tx4 +2.2 dBm
 Dv3 -6.6 dBm
 Line voltage and power: 4020 VAC, 300 KW
22:10 Falla PA4 (Atrad1)
23:00 TX Power sample (-70 dB coupling)
 Tx1 +5.9 dBm
 Tx2 +2.2 dBm
 Tx4 +2.3 dBm
 Dv3 -6.6 dBm

09/05/2014
00:00 Driver 3 (OFF)
00:00 TX Power sample (-70 dB coupling)
 Tx1 +6.2 dBm
 Tx2 +2.2 dBm
 Tx4 +2.2 dBm
 Dv3 off
 Line voltage and power: 4020 VAC, 300 KW
01:00 Transmitter failure (Atrad 3)
01:37 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +2.0 dBm / +5.1 dBm
 Tx4 +2.3 dBm
 Line voltage and power: 4060 VAC, 310 KW
02:00 TX Power sample (-70 dB coupling)
 Tx1 +5.1 dBm
 Tx2 +2.1 dBm / +5.1 dBm
 Tx4 +2.4 dBm
 Line voltage and power: 4060 VAC, 310 KW
03:00 TX Power sample (-70 dB coupling)
 Tx1 +5.1 dBm
 Tx2 +2.1 dBm / +5.1 dBm
 Tx4 +2.4 dBm
 Line voltage and power: 4060 VAC, 310 KW
04:00 TX Power sample (-70 dB coupling)
 Tx1 +5.1 dBm
 Tx2 +2.1 dBm / +5.1 dBm
 Tx4 +2.4 dBm
 Line voltage and power: 4060 VAC, 310 KW
05:00 TX Power sample (-70 dB coupling)
 Tx1 +5.1 dBm
 Tx2 +2.1 dBm / +5.1 dBm
 Tx4 +2.4 dBm
 Line voltage and power: 4060 VAC, 310 KW
06:00 TX Power sample (-70 dB coupling)
 Tx1 +5.1 dBm
 Tx2 +2.1 dBm / +5.1 dBm
 Tx4 +2.4 dBm
 Line voltage and power: 4060 VAC, 310 KW
07:00 TX Power sample (-70 dB coupling)
 Tx1 +5.7 dBm
 Tx2 +2.0 dBm / +5.1 dBm
 Tx4 +2.4 dBm
 Line voltage and power: 4060 VAC, 310 KW
08:00 transmitter Off.

