Opened 11 years ago
#1535 new Transmitters
07 Mayo 23:20 Transmitter Power Measurements
Reported by: | vquesada | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2014_05 Imaging+ISR |
Component: | ISR | Version: | |
Keywords: | Cc: | ||
Parent Tickets: |
Description
20:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.4 dBm
Tx4 +2.4 dBm
D3 -6.6 dBm
Line voltage and power: 4050 VAC, 320 KW
20:40 crowbar por caida de tension
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.4 dBm
Tx4 +2.4 dBm
D3 -6.6 dBm
Line voltage and power: 4050 VAC, 320 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.4 dBm
Tx4 +2.4 dBm
D3 -6.6 dBm
Line voltage and power: 4050 VAC, 320 KW
22:49 Crowbar por caida de tension
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.3 dBm
Tx4 +2.2 dBm
D3 -6.7 dBm
Line voltage and power: 4060 VAC, 320 KW