Opened 11 years ago

#1528 new Transmitters

07 Mayo 07:05 Transmitter Power Measurements

Reported by: vquesada Owned by:
Priority: normal Milestone: 2014_05 Imaging+ISR
Component: ISR Version:
Keywords: Cc:
Parent Tickets:

Description ΒΆ

00:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.3 dBm
Tx4 +1.2 dBm
D3 -6.6 dBm
Line voltage and power: 4050 VAC, 310 KW
00:15 Driver 3 OFF
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.3,+5.2dBm
Tx4 +1.4 dBm
Line voltage and power: 4050 VAC, 310 Kw
01:48 Falla interloock del Tx4 y vuela fusible de fuente +B driver 4
02:30 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +2.3,+5.2dBm
Tx4 +2.0 dBm
Line voltage and power: 4080 VAC, 330 Kw
03:00 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +2.3,+5.2dBm
Tx4 +2.0 dBm
Line voltage and power: 4080 VAC, 330 Kw
04:00 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +2.3,+5.2dBm
Tx4 +2.0 dBm
Line voltage and power: 4080 VAC, 330 Kw
05:00 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +2.3,+5.2dBm
Tx4 +2.0 dBm
Line voltage and power: 4080 VAC, 330 Kw
06:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.3,+5.2dBm
Tx4 +2.0 dBm
Line voltage and power: 4050 VAC, 320 Kw
07:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.3,+5.2dBm
Tx4 +2.0 dBm
Line voltage and power: 4050 VAC, 320 Kw

Subtickets (add)

Change History (0)

Note: See TracTickets for help on using tickets.